Thermo King Alarm Codes Fix
THERMO KING TK 40933-8-CH (Rev 5, 06 October 2003) COLOR CODE DEFINITIONS OK TO RUN CHECK AS SPECIFIED TAKE IMMEDIATE ACTION THESE ARE SUGGESTIONS ONLY. ALWAYS CONSULT YOUR COMPANY FOR FINAL DECISIONS. Num Description Operator Action 31 Check Oil Pressure Switch If the unit shuts down on this alarm code repair immediately. Otherwise, report.
- Details
- Category: Thermoking Tamir ve Bakım
- Published on 11 February 2012
- Written by Super User
- Hits: 16942
Thermo King Alarm Codes Fix Details Category: Thermoking Tamir ve Bakım Published on 11 February 2012. Unit Forced to Low Speed Modulation: 44. Manuals and User Guides for Thermo King TriPac EVOLUTION. We have 1 Thermo King TriPac EVOLUTION manual available for free PDF download: Operator's Manual Thermo King TriPac EVOLUTION Operator's Manual (50 pages). Thermo King Transport Refrigeration Alarm Code #17 Troubleshooting. Introduction: Why take time to write a report on Alarm trouble code #17 thermo king? This is one of the most common codes that owner operators, company drivers and shop technicians deal with.
For the following units;
SB-III 30 SR+,SB-III 30 SR TCI-2, Super II 30 SR+Thermoguard µP IV, Super II SR TCI-2 Thermoguard
µPIV, SB-190, SB-200, SB-300, SB-400, Super II 190 ThermoguardµP VI Controller and SB-210, SB-310,SB-410 with SR-2Controller.
Thermoking Alarm Codes List
![Thermo Thermo](/uploads/1/1/8/7/118758361/746749602.jpg)
0. | No Alarms Exist |
2. | Evaporator Coil Sensor |
3. | Control Return Air Sensor |
4. | Control Discharge Air Sensor |
5. | Ambient Air Sensor |
6. | Coolant Temperature Sensor |
7. | Engine RPM Sensor |
9. | High Evaporator Temperature |
10. | High Discharge Pressure |
11. | Unit Controlling on Alternate Sensor |
12. | Sensor Shutdown |
13. | Sensor Check |
15. | Glow Plug Check/Intake Air Heater |
17. | Engine Failed to Crank |
18. | High Engine Coolant Temperature |
19. | Low Engine Oil Pressure |
20. | Engine Failed to Start |
21. | Cooling Cycle Check |
22. | Heating Cycle Check |
23. | Cooling Cycle Fault |
24. | Heating Cycle Fault |
25. | Alternator Check |
26. | Refrigeration Capacity Check |
27. | Motor RPM High |
28. | Pre-Trip Abort |
29. | Defrost Damper Circuit |
30. | Defrost Damper Stuck Closed |
31. | Oil Pressure Switch |
32. | Refrigeration Capacity Low |
33. | Check Engine RPM |
35. | Run Relay Circuit |
36. | Electric Motor Failed to Run |
37. | Engine Coolant Level |
38. | Electric Phase Reversed |
39. | Water Valve Circuit |
40. | High Speed Circuit |
41. | Check Engine Coolant Temperature |
42. | Unit Forced to Low Speed |
43. | Unit Forced to Low Speed Modulation |
44. | Check Fuel System |
45. | Hot Gas Bypass or Hot Gas Bypass Circuit |
46. | Check Air Flow |
48. | Check Belts or Clutch |
50. | Reset Clock |
53. | Economizer Valve Circuit |
54. | Test Mode Time-Out |
55. | Check Engine Speeds |
61. | Low Battery Voltage Check |
62. | Ammeter Out of Calibration Range |
63. | Engine Stopped – Reason Unknown |
64. | Pretrip Reminder |
66. | Low Engine Oil Level |
67. | Liquid Line Solenoid |
70. | Hourmeters Failure |
71. | Maintenance Hourmeter 4 Exceeds Set Time Limit |
72. | Maintenance Hourmeter 5 Exceeds Set Time Limit |
73. | Maintenance Hourmeter 6 Exceeds Set Time Limit |
74. | Controller Reset to Defaults |
75. | Internal Fault Codes |
76. | Internal Fault Codes |
77. | Internal Fault Codes |
78. | Internal Fault Codes |
79. | Data Log Overflow |
80. | Compressor Temperature Sensor |
81. | High Compressor Temperature |
82. | High Compressor Temperature Shutdown |
83. | Low Coolant Temperature |
84. | Restart Null |
85. | Forced Unit Operation |
86. | Discharge Pressure Sensor |
87. | Suction Pressure Transducer |
89. | Electronic Throttling Valve Circuit |
90. | Electric Overload |
91. | Electric Ready Input |
92. | Sensor Grades Not Set |
93. | Low Compressor Suction |
94. | Loader #1 |
95. | Loader #2 |
96. | Low Fuel Level |
98. | Fuel Level Sensor |
99. | High Compressor Pressure Ratio |
108. | Door Open Time-Out |
109. | High Discharge Pressure |
111. Unit Configuration | |
117. Auto Switch to Electric | |
118. Auto Switch to Diesel | |
121. Liquid Injection Circuit | |
122. Diesel/Electric Relay Circuit | |
127. Setpoint Not Entered | |
128. Engine Run Time Maintenance Reminder #1 | |
129. Engine Run Time Maintenance Reminder #2 | |
130. Electric Run Time Maintenance Reminder #1 | |
131. Electric Run Time Maintenance Reminder #2 | |
132. Total Unit Run Time Maintenance Reminder #1 | |
133. Total Unit Run Time Maintenance Reminder #2 | |
134. Power On Hours | |
135. Spare Digital Inputs | |
136. Spare Digital Outputs | |
203. | Display Return Air Sensor |
204. Display Discharge Air Sensor |